Which Wander (TIE, MTIE, TDEV) and Phase (TE) Masks are Supported by VeEX products?

VeEX test sets supporting synchronization (e.g., PDH, SDH/SONET, SyncE/EEC, CPRI, 1588v2/PTP, etc.) offer a variety of standard built-in PASS/FAIL masks, as well as a Wander Analysis PC application with customizable masks.

VeEX test sets supporting synchronization (e.g., PDH, SDH/SONET, SyncE, CPRI, PTP, etc.) measurements, offer a variety of standard built-in PASS/FAIL masks, as well as a Wander Analysis PC application with customizable masks.

Built-in TIE and TE Masks 

Test sets supporting Wander, Time Error and Phase Error Measurement and Analysis options for different synchronous interfaces or protocols, offer the following set of built-in ITU-T masks:

  • G.811 - Primary Reference Clock (PRC)
  • G.812 - Type I Network Node Clock (SSU) Locked at Constant Temperature
  • G.812 - Type I Network Node Clock (SSU) Locked at Variable Temperature
  • G.812 - Type II & III Network Node Clock (SSU) Locked at Constant Temperature
  • G.813 - Option 1 SDH Equipment slave Clock (SEC) at Constant Temperature
  • G.813 - Option 1 SDH Equipment slave Clock (SEC) at Variable Temperature
  • G.813 - Option 2 SDH Equipment slave Clock (SEC) at Constant Temperature
  • G.823 - PDH Synchronization Interface
  • G.823 - Primary Reference Clock (PRC)
  • G.823 - SDH Equipment Clock (SEC)
  • G.823 - Synchronization Supply Unit (SSU)
  • G.824 - 1544 kbits Reference Signal
  • G.824 - 1544 kbits Reference signal for Option 2 SEC
  • G.8261 - Circuit Emulation Service (CES) Case 1 at 1544 kbits
  • G.8261 - Circuit Emulation Service (CES) Case 1 at 2048 kbits
  • G.8261 - Circuit Emulation Service (CES) Case 2A at 2048 kbits
  • G.8261 - EEC Option 1 SyncE Interface
  • G.8261 - EEC Option 2 SyncE Interface
  • G.8261.1/Y.1361.1 - Packet Equipment Clock-Slave-Frequency (PEC-S-F) Case 3 (n=16 ppb)
  • G.8262 - EEC-Option 1 SyncE NE 2048 kbps Const. Temp.
  • G.8262 - EEC-Option 1 SyncE NE 2048 kbps Var. Temp.
  • G.8262 - EEC-Option 2 SyncE NE 1544 kbps Const. Temp.
  • G.8263 - Packet Equipment Clock-Slave-Frequency (PEC-S-F) at Constant Temperature
  • G.8263 - Packet Equipment Clock-Slave-Frequency (PEC-S-F) at Variable Temperature
  • G.8272 - Primary Reference Time Clock in Locked Mode
  • G.8271.1 - dTE Limit for Level 6A at Point C, Class C T-BC or T-TSC (Table 7.2)
  • G.8271.1 - dTE Limit at Point C, T-BC or T-TSC (Table 7.1)
  • G.8271.1 - dTE LPF Network Limits for PRTC Deployed in Access Network (Clause 7.5)
  • G.8271.2 - TE (LPF) Network Limits at Point D
  • G.8271.2 - TE Network Limits at Points A, B and L

Wander Analysis PC Software

VeEX offers a free Wander Analysis PC Software, which is a simple Wander (MTIE and TDEV) post-processing application, with ITU-T standard and user definable masks.

  • CPRI 2ppb Maximum Link Frequency Offset Contribution (R-18) Master-to-Slave SAP
  • G.811 - Primary Reference Clock (PRC)
  • G.812 - Type I Network Node Clock (SSU) Locked at Constant Temperature
  • G.812 - Type I Network Node Clock (SSU) Locked at Variable Temperature
  • G.812 - Type II & III Network Node Clock (SSU) Locked at Constant Temperature
  • G.813 - Option 1 SDH Equipment slave Clock (SEC) at Constant Temperature
  • G.813 - Option 1 SDH Equipment slave Clock (SEC) at Variable Temperature
  • G.813 - Option 2 SDH Equipment slave Clock (SEC) at Constant Temperature
  • G.823 - PDH Synchronization Interface
  • G.823 - Primary Reference Clock (PRC)
  • G.823 - SDH Equipment Clock (SEC)
  • G.823 - Synchronization Supply Unit (SSU)
  • G.824 - 1544 kbits Reference Signal
  • G.824 - 1544 kbits Reference signal for Option 2 SEC
  • G.8261 - Circuit Emulation Service (CES) Case 1 at 1544 kbits
  • G.8261 - Circuit Emulation Service (CES) Case 1 at 2048 kbits
  • G.8261 - Circuit Emulation Service (CES) Case 2A at 2048 kbits
  • G.8261 - EEC Option 1 SyncE Interface
  • G.8261 - EEC Option 2 SyncE Interface
  • G.8261.1/Y.1361.1 - Packet Equipment Clock-Slave-Frequency (PEC-S-F) Case 3 (n=16 ppb)
  • G.8262 - EEC-Option 1 SyncE NE 2048 kbps Const. Temp.
  • G.8262 - EEC-Option 1 SyncE NE 2048 kbps Var. Temp.
  • G.8262 - EEC-Option 2 SyncE NE 1544 kbps Const. Temp.
  • G.8262.1 - eEEC Wander Output in Locked Mode at Contant Temperature
  • G.8262.1 - eEEC Wander Input Tolerance Level 2
  • G.8263 - Packet Equipment Clock-Slave-Frequency (PEC-S-F) at Constant Temperature
  • G.8263 - Packet Equipment Clock-Slave-Frequency (PEC-S-F) at Variable Temperature
  • G.8271.1 - dTE Limit for Level 6A at Point C, Class C T-BC or T-TSC (Table 7.2)
  • G.8271.1 - dTE Limit at Point C, T-BC or T-TSC (Table 7.1)
  • G.8271.2 - TE (LPF) Network Limits at Point D
  • G.8271.2 - TE Network Limits at Points A, B and L
  • G.8272 - Primary Reference Time Clock (PRTC-A) in Locked Mode
  • G.8272 - Primary Reference Time Clock (PRTC-B) in Locked Mode
  • G.8272.1 - ePRTC Wander Output in Locked Mode
  • G.8273.2 - PTP T-BC TSC Class A dTE LPF Noise Generation Limit at Constant Temperature (7.1.2)
  • G.8273.2 - PTP T-BC TSC Class B dTE LPF Noise Generation Limit at Constant Temperature (7.1.2)
  • G.8273.2 - PTP T-BC TSC Class C dTE LPF Noise Generation Limit at Constant Temperature (7.1.2)
  • G.8273.2 - T-BC Holdover Performance Limit with PTP Loss & Constant Temperature (Sec 7.4.2.2)
  • G.8273.2 - T-BC Holdover Performance Limit with PTP Loss & Variable Temperature (Sec 7.4.2.2)
  • G.8273.2 - T-TSC Holdover Performance Limit with PTP Loss & Constant Temperature (Annex C.2.4.2.2)
  • G.8273.2 - T-TSC Holdover Performance Limit with PTP Loss & Variable Temperature (Annex C.2.4.2.2)

The TIE and TE files may also be converted to be compatible with other wander analyzers, for more in-depth analysis.

Related Test Solutions

  • TX340s - Advanced Multi-Service Test Set

  • RXT-6200 - 100G Multi-Service Test module

  • RXT-3400 - Advanced Multi-Service Test Module

  • MTTplus-340 - Advanced Multi-Service Test Module